New options for increasing the sensitivity, specificity and scope of synergistic contrast magnetic resonance imaging (scMRI) using Multiplied, Added, Subtracted and/or FiTted (MASTIR) pulse sequences release_wkwhyjhlcvgctospjh76dxzajy

by Ya-Jun Ma, Hongda Shao, Shujuan Fan, Xing Lu, Jiang Du, Ian R. Young, Graeme M. Bydder

Published in Quantitative Imaging in Medicine and Surgery by AME Publishing Company.

2020   Volume 10, Issue 10, p2030-2065

Abstract

This paper reviews magnetic resonance (MR) pulse sequences in which the same or different tissue properties (TPs) such as T1 and T2 are used to contribute synergistically to lesion contrast. It also shows how synergistic contrast can be created with Multiplied, Added, Subtracted and/or fiTted Inversion Recovery (MASTIR) sequences, and be used to improve the sensitivity, specificity and scope of clinical magnetic resonance imaging (MRI) protocols. Synergistic contrast can be created from: (i) the same TP, e.g., T1 used twice or more in a pulse sequence; (ii) different TPs such as ρm, T1, T2, and D* used once or more within a sequence, and (iii) additional suppression or reduction of signals from tissues and/or fluids such as fat, long T2 tissues and cerebrospinal fluid (CSF). The short inversion time (TI) inversion recovery (IR) (STIR) and double IR (DIR) sequences usually show synergistic positive contrast for lesions which have increases in both T1 and T2. The diffusion weighted pulsed gradient spin echo (PGSE) sequence shows synergistic contrast for lesions which have an increase in T2 and a decrease in D*; the sequence is both positively weighted for T2 and negatively weighted for D*. In the brain, when an IR sequence nulling white matter has subtracted from it an IR sequence nulling gray matter to form the subtracted IR (SIR) sequence, increases in the single TP T1 between the two nulling points of the original two sequences generate high synergistic positive contrast. In addition, the subtraction to produce the SIR sequence reduces fat and CSF signals. To provide high sensitivity to changes in TPs in disease the SIR sequence can be used (i) alone to provide synergistic T1 contrast as above; (ii) with T2-weighting to provide synergistic T1 and T2 contrast, and (iii) with T2- and D*-weighting to provide synergistic T1, T2, and D* contrast. The SIR sequence can also be used in reversed form (longer TI form minus shorter TI form) to produce very high positive synergistic T1 contrast for reductions in T1, and so increase the positive contrast enhancement produced by clinical gadolinium-based contrast agents (GBCAs) when they reduce T1. The specificity of MRI examinations can be improved by using the reversed SIR sequence with a long echo time (TE) gradient echo as well as echo subtraction to show synergistic high contrast from T1 and T2* shortening produced by organic iron. Other added and subtracted forms of the MASTIR sequence can be used synergistically to selectively show myelin, myelin water and fluids including blood and CSF. Protocols using MASTIR sequences to provide synergistic contrast in MRI of the brain, prostate and articular cartilage are included as illustrative examples, and the features of synergistic contrast MRI (scMRI) are compared to those of multiparametric MRI (mpMRI) and functional MRI (fMRI).
In text/plain format

Archived Files and Locations

application/pdf  4.2 MB
file_7lbp6llo7zghhd775e6c6ytqku
qims.amegroups.com (publisher)
web.archive.org (webarchive)
Read Archived PDF
Preserved and Accessible
Type  article-journal
Stage   published
Year   2020
Language   en ?
Container Metadata
Open Access Publication
Not in DOAJ
In ISSN ROAD
Not in Keepers Registry
ISSN-L:  2223-4306
Work Entity
access all versions, variants, and formats of this works (eg, pre-prints)
Catalog Record
Revision: d02a6577-840e-42c0-9e3c-2b46ac45b2e1
API URL: JSON