Global Longitudinal Strain in Heart Transplantation Recipients Using Different Vendors: Reliability and Validity in a Tertiary Hospital in Colombia. release_vb7rnz5gi5agjjuu7fgzv2dug4

by Oscar Mauricio Perez Fernandez, Hector M. Medina, Mónica López, Madeleine Barrera, Azucena Martinez, Jhonattan Benavides, Juan C. Duran, Gabriel Salazar, Frida Tatiana Manrique

Released as a post by Research Square Platform LLC.

2021  

Abstract

<jats:title>Abstract</jats:title> Global Longitudinal Strain (GLS) is a useful tool to follow-up heart transplant (HT) recipients. Important inter-vendor variability of GLS measurements has been reported in healthy subjects and different conditions, but there is still limited evidence among HT patients. We assessed the reliability and validity of GLS using two vendors (General Electric and Philips) in a group of consecutive and stable adult HT recipients. Patients underwent two concurrent GLS analyses during their echocardiographic follow-up. We evaluated GLS inter-vendor reliability using Bland-Altman's limits of agreement (LOA) plots, computing its coverage probability (CP) and the intraclass correlation coefficient (ICC). Validity was assessed though receiver operating characteristics (ROC) curves, predictive values, sensitivity and specificity of GLS for each vendor to detect a normal left ventricle function.<jats:bold> </jats:bold>78 pairs of GLS studies in 53 stable HT patients were analyzed. We observed a modest inter-vendor reliability with a broad LOA (less than 50% of values falling out our CP of 2% and an ICC of 0.49). ROC analyses (areas under the curve of 0.824 Vs. 0.631, p&lt;0.05) and diagnosis test indices (Sensitivity of 0.73 Vs. 0.64; and Specificity of 0.79 Vs. 0.50) favored GE over Philips. Inter-vendor variability for GLS analysis exceeded clinically acceptable limits in HT recipients. GLS from GE software seemed to show higher validity as compared to Philips'. The present study provides evidence to consider caution for the interpretation of GLS for clinical management in the follow-up of HT patients, especially when GLS is measured by different vendors.
In application/xml+jats format

Archived Files and Locations

application/pdf  1.1 MB
file_dpdlziqitbhbjdbvwqileq3lye
assets.researchsquare.com (publisher)
web.archive.org (webarchive)
application/pdf  1.1 MB
file_cow2betvefcp7j7uige3pc632q
assets.researchsquare.com (web)
web.archive.org (webarchive)
Read Archived PDF
Preserved and Accessible
Type  post
Stage   unknown
Date   2021-06-01
Work Entity
access all versions, variants, and formats of this works (eg, pre-prints)
Catalog Record
Revision: 6fade1ae-df10-4377-b48f-03cd171a1d6c
API URL: JSON