Development and Preliminary Evaluation of a Smartphone App for Measuring Eye Alignment release_toir6jnt6rc6njfok4ph5bnaci

by Shrinivas Pundlik, Matteo Tomasi, Rui Liu, Kevin Houston, Gang Luo

Published in Translational Vision Science & Technology by Association for Research in Vision and Ophthalmology (ARVO).

2019   Volume 8, Issue 1, p19

Abstract

We evaluate a smartphone application (app) performing an automated photographic Hirschberg test for measurement of eye deviations. Three evaluation studies were conducted to measure eye deviations in the horizontal direction. First, gaze angles were measured with respect to the ground truth in nonstrabismic subjects (n = 25) as they fixated monocularly on targets of known eccentricity covering an angular range of approximately ±13°. Second, phoria measurements with the app at near fixation (distance = 40 cm) were compared with the modified Thorington (MT) test in normally-sighted subjects (n = 14). Third, eye deviations using the app were compared to a cover test with prism neutralization (CTPN; n = 66) and Synoptophore (n = 34) in strabismic subjects. Regression analyses were used to compare the app and clinical measurements of the magnitude and direction of eye deviations (prism diopters, Δ). The gaze angles measured by the app closely followed the ground truth (slope = 1.007, R 2 = 0.97, P < 0.001), with a root mean squared error (RMSE) of 2.4Δ. Phoria measurements with the app were consistent with MT (slope = 0.94, R 2 = 0.97, P < 0.001, RMSE = 1.7Δ). Overall, the strabismus measurements with the app were higher than with Synoptophore (slope = 1.15, R 2 = 0.91, P < 0.001), but consistent with CTPN (slope = 0.95, R 2 = 0.95, P < 0.001). After correction of CTPN values for near fixation, the consistency of the app measurements with CTPN was improved further (slope = 1.01). The app measurements of manifest and latent eye deviations were consistent with the comparator clinical methods. A smartphone app for measurement of eye alignment can be a convenient clinical tool and has potential to be beneficial in telemedicine.
In text/plain format

Archived Files and Locations

application/pdf  817.1 kB
file_ne4e33dy4nbn5fj4eqstc675xi
europepmc.org (repository)
web.archive.org (webarchive)
Read Archived PDF
Preserved and Accessible
Type  article-journal
Stage   published
Date   2019-02-08
Language   en ?
DOI  10.1167/tvst.8.1.19
PubMed  30766761
PMC  PMC6369861
Container Metadata
Open Access Publication
In DOAJ
In Keepers Registry
ISSN-L:  2164-2591
Work Entity
access all versions, variants, and formats of this works (eg, pre-prints)
Catalog Record
Revision: d4a12f8b-5c21-4d1f-aa94-6d6b6de451c0
API URL: JSON