Passive Ventilation System Analysis Using Solar Chimney In South Of Algeria
release_sptit46v3balhfs55k5ea4do74
by
B. Belfuguais, S. Larbi
2011
Abstract
The work presented in this study is related to an
energy system analysis based on passive cooling system for
dwellings. It consists to solar chimney energy performances
determination versus geometrical and environmental considerations
as the size and inlet width conditions of the chimney. Adrar site
located in the southern region of Algeria is chosen for this study
according to ambient temperature and solar irradiance technical data
availability. Obtained results are related to the glazing temperature
distributions, the chimney air flow and internal wall temperatures.
The air room change per hour (ACH) parameter, the outlet air
velocity and mass air flow rate are also determined. It is shown that
the chimney width has a significant effect on energy performances
compared to its entry size. A good agreement is observed between
these results and those obtained by others from the literature.