DSF studies towards energy efficiency for a tall building design in the Mediterranean climate release_mxbn3b2hwjfxvlw5zp2ulxeimm

by tanya saroglou, Theodoros Theodosiou, Isaac A. Meir

Entity Metadata (schema)

abstracts[] {'sha1': '27f13bb055377075387773def2faa89dae600a6e', 'content': "Tall buildings around the world are increasing at an accelerating pace. However, this fast-pace development is not in tandem with today's environmental considerations towards reducing high carbon emissions, mainly relating to the building sector (close to 50% of carbon dioxide (CO2) emissions). The vast scale and energy demands of tall buildings call for an in-depth study of this building typology towards improving energy efficiency. An important consideration for lowering energy demands is the configuration of the building envelope that acts as the mediator between indoor and outdoor conditions, according to the climate and microclimate of the building's location. Current architectural practices of fully glazed curtain wall envelopes make this relationship problematic, by resulting in high-energy loads for achieving thermal comfort. Over the last few years, a step forward towards energy efficiency is the use of a double-skin façade (DSF). Its application, however, is lacking consideration of the specific climatic conditions that will essentially result in an energy efficient design. Previous research revealed that the most energy efficient DSF in the Mediterranean climate is with LowE glazing as the outside DSF layer. Further studies on DSF cavity width for a hot climate, were in favour of wider cavities, as these reduce the high cooling loads that are associated with this climate. Additionally, simulations of an office building in the Mediterranean climate, confirmed that cooling energy is also present during winter (airtight DSF), suggesting for a more active DSF envelope design throughout the year. A further study is then conducted through simulations, where the DSF design alternates between an open / closed DSF, and comparisons are made in relation to DSF width, building height above ground, outdoor environmental conditions and interior thermal comfort, for further improving the energy efficiency of tall building design.", 'mimetype': 'application/xml+jats', 'lang': None}
container {'state': 'active', 'ident': 'pkrb3ou6v5ctvl2bjvjckaoktm', 'revision': '800f81fd-fb5a-4b7b-b06b-bc51a4156b5f', 'redirect': None, 'extra': {}, 'edit_extra': None, 'name': 'iCRBE Procedia', 'container_type': 'journal', 'publication_status': None, 'publisher': 'World Energy and Environment Technology Ltd - WEENTECH', 'issnl': '2634-1026', 'issne': None, 'issnp': None, 'wikidata_qid': None}
container_id pkrb3ou6v5ctvl2bjvjckaoktm
contribs[] {'index': 0, 'creator_id': 'yednlye77ffydmfi3ewfjn7ek4', 'creator': {'state': 'active', 'ident': 'yednlye77ffydmfi3ewfjn7ek4', 'revision': '5a3ef049-ba72-40a7-b511-961dbc180377', 'redirect': None, 'extra': None, 'edit_extra': None, 'display_name': 'tanya saroglou', 'given_name': 'tanya', 'surname': 'saroglou', 'orcid': '0000-0002-0322-4670', 'wikidata_qid': None}, 'raw_name': 'T Saroglou', 'given_name': None, 'surname': 'Saroglou', 'role': 'author', 'raw_affiliation': None, 'extra': {'seq': 'first'}}
{'index': 1, 'creator_id': 'tb2r5uq5hjgvncvatahldjtn7y', 'creator': {'state': 'active', 'ident': 'tb2r5uq5hjgvncvatahldjtn7y', 'revision': '3dca7ea8-8b96-4270-8ecb-157e3c7e02c5', 'redirect': None, 'extra': None, 'edit_extra': None, 'display_name': 'Theodoros Theodosiou', 'given_name': 'Theodoros', 'surname': 'Theodosiou', 'orcid': '0000-0002-3385-119X', 'wikidata_qid': None}, 'raw_name': 'T Theodosiou', 'given_name': None, 'surname': 'Theodosiou', 'role': 'author', 'raw_affiliation': None, 'extra': None}
{'index': 2, 'creator_id': 'z5wm5teqfvfbbexl4aeflkxjyq', 'creator': {'state': 'active', 'ident': 'z5wm5teqfvfbbexl4aeflkxjyq', 'revision': '4b7c8edc-83e7-4891-83d0-9608158e176e', 'redirect': None, 'extra': None, 'edit_extra': None, 'display_name': 'Isaac A. Meir', 'given_name': 'Isaac A.', 'surname': 'Meir', 'orcid': '0000-0001-8427-5789', 'wikidata_qid': None}, 'raw_name': 'I. A. Meir', 'given_name': 'I. A.', 'surname': 'Meir', 'role': 'author', 'raw_affiliation': None, 'extra': None}
ext_ids {'doi': '10.32438/icrbe.202026', 'wikidata_qid': None, 'isbn13': None, 'pmid': None, 'pmcid': None, 'core': None, 'arxiv': None, 'jstor': None, 'ark': None, 'mag': None, 'doaj': None, 'dblp': None, 'oai': None, 'hdl': None}
files []
filesets []
issue
language en
license_slug
number
original_title
pages 165-179
publisher World Energy and Environment Technology Ltd - WEENTECH
refs[] {'index': 0, 'target_release_id': None, 'extra': {'doi': '10.18356/cd4eece8-en', 'unstructured': "[1]\tUnited Nations, World's population increasingly urban with more than half living in urban areas | UN DESA | United Nations Department of Economic and Social Affairs, (2014). https://www.un.org/development/desa/en/news/population/world-urbanization-prospects.html (accessed January 27, 2016)."}, 'key': 'ref0', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 1, 'target_release_id': None, 'extra': {'doi': '10.3850/s2382581216010905', 'unstructured': '[2]\tCTBUH_ResearchReport, CTBUH Year in Review\u202f: Tall Trends of 2018 Tall Building Completions Maintain Momentum in 2018, CTBUH J. (2019).'}, 'key': 'ref1', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 2, 'target_release_id': None, 'extra': {'unstructured': '[3]\tD. Safarik, P. Moore, W. Urban, E. Fraser, F. Priest, M. Cesarz, G. Murray, R.A.M.S. Architects, R. Lu, R. Haskoningdhv, S.D. Lindsey, A.B. Lee, T. Kinzl, A. Hall, M. Morris, A. Fender, B. Mohandas, J. Paul, R. Azari, L. Lindsey, D. Shook, J. Zhang, 2019 Year in Review: Another Record Year for Supertall Completions, Counc. Tall Build. Urban Habitat. (2020).'}, 'key': 'ref2', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 3, 'target_release_id': None, 'extra': {'unstructured': '[4]\tEU, Directive 2010/31/EU of the European Parliament and of the Council of 19 May 2010 on the energy performance of buildings, Publ. Off. J. Eur. Union. (2010).'}, 'key': 'ref3', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 4, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2004.05.002', 'unstructured': '[5]\tC.K. Cheung, R.J. Fuller, M.B. Luther, Energy-efficient envelope design for high-rise apartments, Energy Build. 37 (2005) 37–48. doi:10.1016/j.enbuild.2004.05.002.'}, 'key': 'ref4', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 5, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2004.07.003', 'unstructured': '[6]\tF. Yik, Cooling energy evaluation for high-rise residential buildings in Hong Kong, Energy Build. 37 (2005) 345–351. doi:10.1016/j.enbuild.2004.07.003.'}, 'key': 'ref5', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 6, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2017.05.057', 'unstructured': '[7]\tT. Saroglou, I.A. Meir, T. Theodosiou, B. Givoni, Towards energy efficient skyscrapers, Energy Build. 149 (2017) 1–13. doi:10.1016/j.enbuild.2017.05.057.'}, 'key': 'ref6', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 7, 'target_release_id': None, 'extra': {'unstructured': '[8]\tB. Givoni, Man Climate Architecture, Van Nostrand Reinhold, New York, 1969.'}, 'key': 'ref7', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 8, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2011.10.038', 'unstructured': '[9]\tI.Y. Choi, S.H. Cho, J.T. Kim, Energy consumption characteristics of high-rise apartment buildings according to building shape and mixed-use development, Energy Build. 46 (2012) 123–131. doi:10.1016/j.enbuild.2011.10.038.'}, 'key': 'ref8', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 9, 'target_release_id': None, 'extra': {'unstructured': '[10]\tF. Allard, M. Santamouris, Natural Ventilation in Buildings: A Design Handbook, Routledge:New York, 1998.'}, 'key': 'ref9', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 10, 'target_release_id': None, 'extra': {'doi': '10.7763/jocet.2016.v4.258', 'unstructured': '[11]\tM.M.S. Ahmed, A.K. Abel-Rahman, A.H.H. Ali, M. Suzuki, Double Skin Façade: The State of Art on Building Energy Efficiency, J. Clean Energy Technol. 4 (2015) 84–89. doi:10.7763/JOCET.2016.V4.258.'}, 'key': 'ref10', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 11, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2014.03.002', 'unstructured': '[12]\tJ. Joe, W. Choi, Y. Kwak, J.H. Huh, Optimal design of a multi-story double skin facade, Energy Build. 76 (2014) 143–150. doi:10.1016/j.enbuild.2014.03.002.'}, 'key': 'ref11', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 12, 'target_release_id': None, 'extra': {'doi': '10.1016/j.rser.2016.01.130', 'unstructured': '[13]\tA. Ghaffarianhoseini, A. Ghaffarianhoseini, U. Berardi, J. Tookey, D. Hin, W. Li, S. Kariminia, Exploring the advantages and challenges of double-skin façades ( DSFs ), Renew. Sustain. Energy Rev. 60 (2016) 1052–1065. doi:10.1016/j.rser.2016.01.130.'}, 'key': 'ref12', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 13, 'target_release_id': None, 'extra': {'doi': '10.1016/j.rser.2019.06.044', 'unstructured': '[14]\tT. Saroglou, T. Theodosiou, B. Givoni, I.A. Meir, A study of different envelope scenarios towards low carbon high-rise buildings in the Mediterranean climate - can DSF be part of the solution?, Renew. Sustain. Energy Rev. 113 (2019) 109237. doi:10.1016/j.rser.2019.06.044.'}, 'key': 'ref13', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 14, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2019.109641', 'unstructured': '[15]\tT. Saroglou, T. Theodosiou, B. Givoni, I.A. Meir, Studies on the optimum double-skin curtain wall design for high-rise buildings in the Mediterranean climate, Energy Build. 208 (2020) 109641. doi:10.1016/j.enbuild.2019.109641.'}, 'key': 'ref14', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 15, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2017.03.038', 'unstructured': '[16]\tA. Dama, D. Angeli, O.K. Larsen, Naturally ventilated double-skin façade in modeling and experiments, Energy Build. 144 (2017) 17–29. doi:10.1016/j.enbuild.2017.03.038.'}, 'key': 'ref15', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 16, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2012.02.047', 'unstructured': '[17]\tW. Choi, J. Joe, Y. Kwak, J.H. Huh, Operation and control strategies for multi-storey double skin facades during the heating season, Energy Build. 49 (2012) 454–465. doi:10.1016/j.enbuild.2012.02.047.'}, 'key': 'ref16', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 17, 'target_release_id': None, 'extra': {'doi': '10.1016/j.rser.2015.10.075', 'unstructured': '[18]\tF. Pomponi, P.A.E. Piroozfar, R. Southall, P. Ashton, E.R.P. Farr, Energy performance of Double-Skin Façades in temperate climates\u202f: A systematic review and meta-analysis, Renew. Sustain. Energy Rev. 54 (2016) 1525–1536. doi:10.1016/j.rser.2015.10.075.'}, 'key': 'ref17', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 18, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2007.02.025', 'unstructured': '[19]\tN. Hamza, Double versus single skin facades in hot arid areas, Energy Build. 40 (2008) 240–248. doi:10.1016/j.enbuild.2007.02.025.'}, 'key': 'ref18', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 19, 'target_release_id': None, 'extra': {'doi': '10.1016/j.rser.2017.08.061', 'unstructured': '[20]\tE. Halawa, A. Gha, A. Gha, J. Trombley, N. Hassan, M. Baig, M. Azzam, A review on energy conscious designs of building façades in hot and humid climates\u202f: Lessons for ( and from ) Kuala Lumpur and Darwin, Renew. Sustain. Energy Rev. 82 (2018) 2147–2161. doi:10.1016/j.rser.2017.08.061.'}, 'key': 'ref19', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 20, 'target_release_id': None, 'extra': {'doi': '10.1016/j.rser.2010.10.016', 'unstructured': '[21]\tM.A. Shameri, M.A. Alghoul, K. Sopian, M.F.M. Zain, O. Elayeb, Perspectives of double skin fac ̧ ade systems in buildings and energy saving, Renew. Sustain. Energy Rev. 15 (2010) 1468–1475. doi:10.1016/j.rser.2010.10.016.'}, 'key': 'ref20', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 21, 'target_release_id': None, 'extra': {'doi': '10.1080/17512549.2012.740209', 'unstructured': '[22]\tI.A. Meir, A. Peeters, D. Pearlmutter, S. Halasah, Y. Garb, J.-M. Davis, An assessment of regional constraints, needs and trends, Adv. Build. Energy Res. 6 (2012) 173–211. doi:10.1080/17512549.2012.740209.'}, 'key': 'ref21', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 22, 'target_release_id': None, 'extra': {'unstructured': '[23]\tR. Knowles, The Solar Envelope, 1999. http://www-bcf.usc.edu/~rknowles/sol_env/sol_env.html.'}, 'key': 'ref22', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 23, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2014.12.044', 'unstructured': '[24]\tP. Lotfabadi, Solar considerations in high-rise buildings, Energy Build. 89 (2015) 183–195. doi:10.1016/j.enbuild.2014.12.044.'}, 'key': 'ref23', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 24, 'target_release_id': None, 'extra': {'doi': '10.1063/1.3490510', 'unstructured': '[25]\tP.A. Irwin, Vortices and tall buildings: A recipe for resonance, Phys. Today. 63 (2010) 68–69. doi:10.1063/1.3490510.'}, 'key': 'ref24', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 25, 'target_release_id': None, 'extra': {'unstructured': '[26]\tJ. Erich, Wind and Urban Climates, Fifth Conf. Urban Environ. (2004). http://ams.confex.com/ams/AFAPURBBIO/techprogram/paper_80813.htm.'}, 'key': 'ref25', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 26, 'target_release_id': None, 'extra': {'unstructured': '[27]\tInternational Association for Urban Climate World Meteorological Organization, Sixth International Conference on Urban Climate, in: SIXTH INTERNATIONAL CONFERENCE ON URBAN CLIMATE, Göteborg, 2006: p. 896.'}, 'key': 'ref26', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 27, 'target_release_id': None, 'extra': {'doi': '10.5359/jawe.2006.529', 'unstructured': '[28]\tF. Joerg, Recommendations of the COST action C14 on the use of CFD in predicting pedestrian wind environment, Fourth Int. Symp. Comput. Wind Eng. (2006) 529–532.'}, 'key': 'ref27', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 28, 'target_release_id': None, 'extra': {'doi': '10.1016/j.jweia.2008.02.058', 'unstructured': '[29]\tY. Tominaga, A. Mochida, R. Yoshie, H. Kataoka, T. Nozu, M. Yoshikawa, T. Shirasawa, AIJ guidelines for practical applications of CFD to pedestrian wind environment around buildings, J. Wind Eng. Ind. Aerodyn. 96 (2008) 1749–1761. doi:10.1016/j.jweia.2008.02.058.'}, 'key': 'ref28', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 29, 'target_release_id': None, 'extra': {'unstructured': '[30]\tC. Drew, A. Smith, G. Gill, K.F. Nova, A. Smith, G. Gill, K. Fanning, A. Smith, G. Gill, C. Drew, K.F. Nova, K. Fanning, A. Smith, G. Gill, W.M. Street, The Environmental Impact of Tall vs Small: A Comparative Study, Int. J. High-Rise Build. 4 (2015) 109–116.'}, 'key': 'ref29', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 30, 'target_release_id': None, 'extra': {'unstructured': '[31]\tP.G. Ellis, P.A. Torcellini, Simulating tall buildings using EnergyPlus, Ninth Int. Build. Perform. Simul. Assoc. Conf. Exhib. (Building Simul. 2005). (2005).'}, 'key': 'ref30', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 31, 'target_release_id': None, 'extra': {'unstructured': '[32]\tASHRAE, Airflow around buildings, in: ASHRAE (Ed.), ASHARE Fundam. Am. Soc. Heating, Refrig. Air Cond. Eng., Altanta, GA, 2009.'}, 'key': 'ref31', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 32, 'target_release_id': None, 'extra': {'doi': '10.2172/1254831', 'unstructured': '[33]\tNOAA NASA and USAI, U.S. Standard Atmosphere 1976, National Oceanic and Atmospheric Administration, National Aeronautics and Space Administration, United States Air Force, Washington, D.C., 1976. doi:10.1017/CBO9781107415324.004.'}, 'key': 'ref32', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 33, 'target_release_id': None, 'extra': {'unstructured': '[34]\tP.O. Fanger, Thermal Comfort: Analysis and applications in environmental engineering, McGraw-Hill, 1970.'}, 'key': 'ref33', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 34, 'target_release_id': None, 'extra': {'doi': '10.1016/j.rser.2014.05.024', 'unstructured': '[35]\tP. Lotfabadi, High-rise buildings and environmental factors, Renew. Sustain. Energy Rev. 38 (2014) 285–295. doi:doi:10.1016/j.rser.2014.05.024.'}, 'key': 'ref34', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 35, 'target_release_id': None, 'extra': {'doi': '10.1017/cbo9781107415324.004', 'unstructured': '[36]\tI.G. Capeluto, C.E. Ochoa, On the determination of climate strategies for a multifunctional energy retrofit facade system, Cisbat Conf. 1 (2013) 49–54. doi:10.1017/CBO9781107415324.004.'}, 'key': 'ref35', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 36, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2014.06.036', 'unstructured': '[37]\tC. Zhou, Z. Wang, Q. Chen, Y. Jiang, J. Pei, Design optimization and field demonstration of natural ventilation for high-rise residential buildings, Energy Build. 82 (2014) 457–465. doi:10.1016/j.enbuild.2014.06.036.'}, 'key': 'ref36', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 37, 'target_release_id': None, 'extra': {'doi': '10.1016/j.apenergy.2017.02.041', 'unstructured': '[38]\tZ. Tong, Y. Chen, A. Malkawi, Estimating natural ventilation potential for high-rise buildings considering boundary layer meteorology, Appl. Energy. 193 (2017) 276–286. doi:10.1016/j.apenergy.2017.02.041.'}, 'key': 'ref37', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 38, 'target_release_id': None, 'extra': {'doi': '10.4324/9780203720042', 'unstructured': '[39]\tA. Wood, R. Salib, Natural Ventilation in High-Rise Office Buildings, CTBUH Techical Guide, Routledge, New York and London, 2013. https://store.ctbuh.org/PDF_Previews/Reports/2012_CTBUHNaturalVentilationGuide_Preview.pdf (accessed January 28, 2016).'}, 'key': 'ref38', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 39, 'target_release_id': None, 'extra': {'doi': '10.1002/bapi.200910040', 'unstructured': '[40]\tV. Huckemann, É.B. Leão, M. Leão, Acoustic comfort in office buildings with double skin glass façades, Bauphysik. 31 (2009) 305–312. doi:10.1002/bapi.200910040.'}, 'key': 'ref39', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 40, 'target_release_id': None, 'extra': {'doi': '10.1016/j.rser.2013.02.029', 'unstructured': '[41]\tL.F. Cabeza, A. De Gracia, A. Castell, L. Navarro, E. Oro, Numerical modelling of ventilated facades\u202f: A review, Renew. Sustain. Energy Rev. 22 (2013) 539–549. doi:10.1016/j.rser.2013.02.029.'}, 'key': 'ref40', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 41, 'target_release_id': None, 'extra': {'doi': '10.1016/j.rser.2012.02.059', 'unstructured': '[42]\tG. Quesada, D. Rousse, Y. Dutil, M. Badache, S. Hallé, A comprehensive review of solar facades . Transparent and translucent solar facades, Renew. Sustain. Energy Rev. 16 (2012) 2643–2651. doi:10.1016/j.rser.2012.02.059.'}, 'key': 'ref41', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 42, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2008.11.008', 'unstructured': '[43]\tM. Haase, F. Marques Da Silva, A. Amato, Simulation of ventilated facades in hot and humid climates, Energy Build. 41 (2009) 361–373. doi:10.1016/j.enbuild.2008.11.008.'}, 'key': 'ref42', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 43, 'target_release_id': None, 'extra': {'unstructured': '[44]\tL.H. Ismail, M. Sibley, Bioclimatic performance of high rise office buildings: A case study in Penang Island, PLEA 2006 - 23rd Int. Conf. Passiv. Low Energy Archit. Conf. Proceedings, Geneva, Switzerland, 6-8 Sept. 2006. (2006).'}, 'key': 'ref43', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 44, 'target_release_id': None, 'extra': {'unstructured': '[45]\tJ. Hensen, M. Bartak, F. Kal, Modeling and Simulation of a Double-Skin Façade System, Am. Soc. Heating, Refrig. Air-Conditioning Eng. 108 (2002).'}, 'key': 'ref44', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 45, 'target_release_id': None, 'extra': {'unstructured': '[46]\tH. Poirazis, Double Skin Façades for Office Buildings Literature Review, Div. Energy Build. Des. Dep. Constr. Archit. Lund Inst. Technol. Lund. Report EBD (2004) 196.'}, 'key': 'ref45', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 46, 'target_release_id': None, 'extra': {'unstructured': '[47]\tAirflow around buildings, in: ASHRAE (Ed.), in: ASHARE Fundam. Am. Soc. Heating, Refrig. Air Cond. Eng., ASHRAE, Altanta, GA, 2009.'}, 'key': 'ref46', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 47, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2013.01.015', 'unstructured': '[48]\tJ. Joe, W. Choi, H. Kwon, J.H. Huh, Load characteristics and operation strategies of building integrated with multi-story double skin facade, Energy Build. 60 (2013) 185–198. doi:10.1016/j.enbuild.2013.01.015.'}, 'key': 'ref47', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 48, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2016.02.045', 'unstructured': '[49]\tA.S. Ancrossed D Signelkovic, I. Mujan, S. Dakic, Experimental validation of a EnergyPlus model: Application of a multi-storey naturally ventilated double skin facade, Energy Build. 118 (2016) 27–36. doi:10.1016/j.enbuild.2016.02.045.'}, 'key': 'ref48', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 49, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2013.09.049', 'unstructured': '[50]\tA.L.S. Chan, T.T. Chow, Calculation of overall thermal transfer value (OTTV) for commercial buildings constructed with naturally ventilated double skin façade in subtropical Hong Kong, Energy Build. 69 (2014) 14–21. doi:10.1016/j.enbuild.2013.09.049.'}, 'key': 'ref49', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 50, 'target_release_id': None, 'extra': {'doi': '10.1016/j.enbuild.2014.02.043', 'unstructured': '[51]\tN.M. Mateus, A. Pinto, G.C. Da Graca, Validation of EnergyPlus thermal simulation of a double skin naturally and mechanically ventilated test cell, Energy Build. 75 (2014) 511–522. doi:10.1016/j.enbuild.2014.02.043.'}, 'key': 'ref50', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 51, 'target_release_id': None, 'extra': {'unstructured': '[52]\tK. Deuk-Woo, P. Cheol-Soo, A Heterogenenous System Simulation Of A Double-Skin Facade, in: 12th Conf. Int. Build. Perform. Simul. Assoc. Sydney, 14-16 Novemb., Proceedings of Building Simulation 2011, 2011.'}, 'key': 'ref51', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 52, 'target_release_id': None, 'extra': {'doi': '10.3850/s2382581216010905', 'unstructured': '[53]\tCTBUH, Calculating the height of a tall building where only the number of stories is known, Www.Ctbuh.Org. 9 (2015) 1–3. http://www.ctbuh.org/TallBuildings/HeightStatistics/HeightCalculator/tabid/1007/language/en-GB/Default.aspx (accessed June 15, 2016).'}, 'key': 'ref52', 'year': None, 'container_name': None, 'title': None, 'locator': None}
{'index': 53, 'target_release_id': None, 'extra': {'unstructured': '[54]\tSII, SI -5281 part 3, Sustainable Building (Green-Building), Office Building Guidelines, Technical guide, Standards Institute of Israel, Tel Aviv, 2011.'}, 'key': 'ref53', 'year': None, 'container_name': None, 'title': None, 'locator': None}
release_date 2020-09-23
release_stage published
release_type article-journal
release_year 2020
subtitle
title DSF studies towards energy efficiency for a tall building design in the Mediterranean climate
version
volume
webcaptures []
withdrawn_date
withdrawn_status
withdrawn_year
work_id 2xpaojx5nbbavnvv35o3ao2sb4
As JSON via API

Extra Metadata (raw JSON)

crossref.archive ['Internet Archive']
crossref.license [{'URL': 'http://weentechpublishers.com/conference.aspx', 'content-version': 'vor', 'delay-in-days': 0, 'start': '2020-09-23T00:00:00Z'}]
crossref.type journal-article