TOF spectroscopy measurement using waveform digitizer release_k5fs5dpjuffv5mnxznbsopwtzm

by Longxiang Liu, Hongwei Wang, Yugang Ma, Xiguang Cao, Xiangzhou Cai, Jingen Chen, Guilin Zhang, Jianlong Han, Guogiang Zhang, Jifeng Hu, Xiaohe Wang

Released as a article .

2015  

Abstract

The photoneutron source (PNS, phase 1), an electron linear accelerator (linac)-based pulsed neutron facility that uses the time-of-flight (TOF) technique, was constructed for the acquisition of nuclear data from the thorium molten salt reactor(TMSR) at the Shanghai Institute of Applied Physics (SINAP). The neutron detector signal, with the information on the pulse arrival time, pulse shape, and pulse height, was recorded by using a waveform digitizer (WFD). By using the pulse height and pulse-shape discrimination (PSD) analysis to identify neutrons and γ-rays, the neutron TOF spectrum was obtained by employing a simple electronic design, and a new WFD-based DAQ system was developed and tested in this commissioning experiment. The developed DAQ system is characterized by a very high efficiency with respect to millisecond neutron TOF spectroscopy
In text/plain format

Archived Files and Locations

application/pdf  6.5 MB
file_blanvj3ib5amxmldt4q5rc73wu
web.archive.org (webarchive)
arxiv.org (repository)
Read Archived PDF
Archived
Type  article
Stage   submitted
Date   2015-08-24
Version   v1
Language   en ?
arXiv  1508.05708v1
Work Entity
access all versions, variants, and formats of this works (eg, pre-prints)
Catalog Record
Revision: 078db556-4257-4b33-8b4a-feaa0653543a
API URL: JSON