Nondestructive Beam Current Monitor for the 88-inch Cyclotron release_k4jy72rkh5ahjclk2mptspvnlq

by Michel Kireeff Covo, Petit-Jean-Genaz, Christine (Ed.), Arduini, Gianluigi (Ed.), Michel, Peter (Ed.), Volker RW Schaa

Published by JACoW, Geneva, Switzerland.

2014   Volume IPAC2014, Germany

Abstract

A fast current transformer is mounted in the staging line of the Berkeley 88-inch isochronous cyclotron. The measured signal is amplified and connected to the input of a lock-in amplifier. The lock-in amplifier detects the signal vector from the input signal at the RF reference frequency of the cyclotron second harmonic. The magnitude of the signal detected is calibrated against a Faraday cup and shows the beam current leaving the cyclotron.
In text/plain format

Archived Files and Locations

application/pdf  622.7 kB
file_znsjjpjeaffabibqvcbfwne5ze
accelconf.web.cern.ch (web)
web.archive.org (webarchive)
Read Archived PDF
Preserved and Accessible
Type  article-journal
Stage   published
Date   2014-07-14
Work Entity
access all versions, variants, and formats of this works (eg, pre-prints)
Catalog Record
Revision: 2afb9018-4dcf-482e-a39e-fbd03a1694de
API URL: JSON