Optimization of PID Controller Parameters in the Case of Batch Styrene Suspension Polymerization release_42ijbdajfrbkpgjtgr6kwr7coq

by G.R. Palau, V. Lavric

Published in Chemical Engineering Transactions by AIDIC Servizi S.r.l..

2013   Volume 35

Abstract

The highly exothermal polymerization reaction needs an efficient cooling system in order to avoid thermal runaways. The thermal agent flowrate or inlet temperature may represent the manipulated variable (MV) that the controller should adjust according to a set of laws to achieve a suitable goal. The laws the controller observes determine the class it belongs to: proportional (P), integral (I), derivative (D) or a combination of them. Due to its versatility and better performances, the PID controller was our choice. Its parameters can be set either by applying a set of rules, like Ziegler-Nichols' or Cohen-Coon's, or by searching for the optimal values fulfilling a performance criterion concerning the polymerization process, the optimization algorithm being suitably selected. One possible choice as performance criterion could be the distance between the actual reactor operating temperature and a set point. An interesting case study for applying this solution strategy is the batch reactor for the polymerization of styrene in suspension due to the two-step heat transfer: a) directly, from the monomer-polymer drops of given distribution to the continuous phase and b) indirectly, from the latter to the thermal agent, through the reactor wall. This way, the monomer/polymer drop temperature (which is function of drop's size as well and determines the polymer characteristics) can be influenced by the way the system responds to the adjustments made by the controller. The drop-water interface acts like a heat sink, but the average temperature of the drop is maintained at a higher level as compared to water by the ongoing polymerization reaction. The larger the drops, the higher the temperature differences between them and the continuous medium, with implications, as is to be shown by this contribution, on the optimized PID controller parameters.
In text/plain format

Archived Files and Locations

application/pdf  618.3 kB
file_qschhdncvrdbfiuvzq5emwy6f4
www.aidic.it (publisher)
web.archive.org (webarchive)
Read Archived PDF
Preserved and Accessible
Type  article-journal
Stage   published
Year   2013
Language   en ?
Container Metadata
Not in DOAJ
Not in Keepers Registry
ISSN-L:  1974-9791
Work Entity
access all versions, variants, and formats of this works (eg, pre-prints)
Catalog Record
Revision: 16865b26-e012-4f4b-8461-d24c7c4b10a4
API URL: JSON